Is it normal for a brand new furnace in the attic to shake this much?

Nov 19, 2026 Last reply: 21 hours ago 5 Replies
Saved reading

First reply

CobaltHeron228

You're not being paranoid. A furnace that new shouldn't shake enough for the inspector to flag it, let alone enough for you to feel it from outside the unit. The only thing in there that really moves is the blower wheel, so if the whole cabinet is vibrating, that's almost…

Read the full reply

So we just bought a house and the furnace up in the attic is a 2026 model, still under warranty. During the general inspection the inspector flagged that it was shaking, so the seller had an HVAC company come out and take a look. Here's the part that bugs me. The company said they couldn't find anything wrong with it. I was not there for the visit so I don't know how thoroughly they checked, but the shaking seems really excessive to me. It's installed horizontally in the attic and when it runs you can tell something is moving more than it shold.



Maybe I'm being paranoid since I'm new to the house, but I find it hard to belive a furnace this new shakes that much for no reason. Anyone dealt with something like this before or have any thoughts on what I should do next?


You're not being paranoid. A furnace that new shouldn't shake enough for the inspector to flag it, let alone enough for you to feel it from outside the unit. The only thing in there that really moves is the blower wheel, so if the whole cabinet is vibrating, that's almost always the culprit. It behaves exactly like an unbalanced tire on a car. Either something is stuck in the wheel, or the wheel itself is bad or deformed. A piece of debris, a loose chunk of insulation from an attic install like yours, even a paper document that got sucked in, any of that will throw the wheel off balance and shake the whole cabinet.

And that last one isn't as crazy as it sounds. I've heard of installation manuals and warranty paperwork ending up inside blower housings because someone set them on an open unit during the install. Looking at your photo, with the documents in that clear sleeve just sitting on top of the cabinet, it's easy to see how paper ends up where it shouldn't when the door comes off. Attics are dusty, sloppy job sites. As for the HVAC company finding nothing wrong, that bugs me too. It's the kind of thing you can miss if the furnace happens to run quiet while they're standing there, or if they just listened and didn't pull the blower to look at the wheel. Since you weren't there, you have no idea what they actually did. I'd call them back and ask specifically whether they inspected and cleaned the blower wheel, and I'd want to be present for it. You're still under warranty, so if the wheel itself is deformed, that's a warranty part, but somebody has to actually find it first. One other thought from your photo: with the unit mounted horizontally like that, any imbalance gets amplified because the cabinet has nothing damping it. So even a small bit of debris in the wheel can look like a lot of shaking. Trust your gut on this one.

One thing in your photo I haven't seen anyone bring up yet is the cabinet doors, they look like they're on backwards to me. Which makes me wonder how carefully that unit was handled overall. If the doors got hung that way during the attic install, it makes you question what else got rushed up there. Might be nothing, but I'd have whoever comes back double check the whole install, not just the blower, while the warranty's still fresh.

Back when furnaces sat in basements and you sized duct by hand with a rule of thumb, an undersized return was the thing we checked right after the blower. That point still holds up today. You've got this thing laid on its side up in an attic with nowhere for air to breathe easy, and if the return duct is too small for the new system the cabinet will shake from the strain alone. It's not just about what's stuck in the wheel. And looking at your photo, that attic tunnel looks tight all around, the unit's really boxed in there. Did the HVAC company check the duct sizing at all, or only the furnace itself? Big difference between the two answers.

That clear sleeve of paperwork sitting on top of the cabinet in your photo is exactly the kind of thing I'd want gone before anyone opens the blower door up there. When I set up a job I learned the hard way to put documentation on the subfloor, becuase paper migrates into whatever opening is nearest. Also, were the sellers' HVAC folks the ones who installed the unit or a diferent company? Makes a difference for how the warranty claim goes if the wheel does turn out to be bad.

Update - so reading through these, the blower wheel idea makes a lot of sense, and now I'm kicking myself that the HVAC company said they found nothing. If something were stuck in the wheel or it was bent, would that be obvious the moment they pulled the blower door, or is it the kind of thing a rushed tech could miss? Also went back and looked at my photo after the comment about the cabinet doors and honestly they do look flipped.