It happens that Andy Burns formulated :
Maybe play it safe and isolate the supply anyway?
It happens that Andy Burns formulated :
Maybe play it safe and isolate the supply anyway?
Transco also used to have a clear process, and direct links to suppliers, if they saw evidence of tampering or had reason to suspect it.
I recall once being offered a black box with a mains lead input and a couple of flex outputs with insulated sections terminating in thin spikes to push up into the two end connections of a domestic electricity meter. Doing so injected a current into the current coil of the meter and depending on which way round either reversed or speeded up the meter. Versions were available to run the old disc meters backwards faster but led to the risk of negative readings if used to excess. Asking price in the pubs around Doncaster was fifty quid if I recall correctly. I believe digital meters won't run backwards but they will probably be made to run slower/stop while the cheat device is in operation.
I have never seen a working meter blocker.
I think they work for the sellers? ;-)
Tim
If you have two spikes into the cables either side of a meter and a dead short between them it cannot not work to some extent. The rest is probably bollocks
People usually overlook the obvious when tampering/bypassing meters.
It needs a neutral and they always go for the live.
At least an undetecable one!
There was an electric meter museum round here. The man running it (Wednesdays
2-6 p.m. or something) had -- he had worked as a meter reader before retirement. He said to me: Some builders had a heated shack, heat electric off a meter inside. He was supposed to read, that meter -- they had very effectively stopped the meter by pounding a cold chisel into the face of the meter... He told them he was going out for a smoke, and he would then come back to find the chisel gone, please, and they would then please report a regrettable meter accident to the power co. immediately -- tools, building site, just happened now, sir, so sorry -- or else. And besides they were lucky not to have electrocuted themselves.And these Leftpondian meters
allegedly have the dials stamped with a fine but loose powder, rather than paint, so the faintest touch will smudge the print. (The glass comes off, a metal ring and seal are there to prevent that, but easy enough to remove...)
Thomas Prufer
As I understood it the two spikes were connected to a transformer which injected a current in antiphase to the load passing through the meter current coil.
Have something to add? Share your thoughts — no account required.
Ask the community — no account required