Quandary regarding bathroom ceiling vapour barrier

Hi Folks, Okays, I have done some searches, but nothing definitive has appeared, hence this post.

Our bathroom has an adjoining "cubicle" area which (I guess) was designed as a shower cabinet (all three walls of the cubicle are solid block walls; the cubicle is accessible from the bathroom proper). There used to be a shower installed in there, but to reduce the height a false pine ceiling (tongue and groove) was installed hence isolating a cuboid space of about two feet in height above the shower. This false ceiling comprised of a perimeter of two-by-two wood, a strap across the middle and the 10mm pine boards nailed up to this frame.

We are refurbishing the whole bathroom, hence my curiosity got the better of me and thus I decided to remove the false pine ceiling. The plasterboard ceiling above the (now removed) false ceiling was painted a Barbie Pink colour, but it also was significantly covered in black mould.

I plan to remove this plasterboard (taking precautions not to breathe the ensuing dust) and reinstate it. I plan to install a vapour barrier above the new plasterboard first.

When I showed a friend this present state of ceiling and explained what I planned to do, he mentioned that the addition of a vapour barrier was more likely to induce such fungal growth than if I didn't install one.

I wonder if he's right (hence this post): would it not be true that adding a vapour barrier prevents the dissemination of humid air hence the humidity is higher within the bathroom? Or is this a half-truth: in the absence of forced ventilation it is true that no vapour barrier is better than a vapour barrier?

I'm no expert at this, hence it's time to humbly engage the collective wisdom of the group.

Thanks in advance

Mungo

Reply to
Mungo Henning
Loading thread data ...

I think he is likely right.

What you need is a vapopur barrier immediately above the false ceiling, not a nice void that traps moist air above it.

OTOH if the false ceiling is staying out, then you should use a vapour barrier at that point AND a bathroom fan..

Reply to
The Natural Philosopher

I covered my enclosed shower ceiling with ply then ,then glued some upvc sheet, sealing the edges with upvc quandrant beading and silicone.,very neat and no mould