Plumbing

Feb 21, 2013 3 Replies

How do I fit a honeywell replacement power head it's a 3 position diverted.


I *think* it's just a case of removing the cover (power off first!) and then you should see a couple of slotted dome headed screws holding the baseplate of the powerhead to the water valve. Undo, screw on new one. Connect wires, job done.

Tim

That's right, if it is a removeable one. Honeywell make 2 sorts, and there are lots of the older ones out there. The removeable ones have a small nipple/bump at one end of the top, outer, cover. If you take off the one without a nipple, you'll have a water leak.

In message , Jrwart writes

Since you're posting from diybanter and are obviously too stupid - get a man in

Join the Discussion