Having achieved SOME stabiliy by not using one ring at all, suddenly the damned thing was tripping again and I managed to get it consistent enough to narrow it down to the system boiler.
Engineer came, and it didnt trip. Pump was OK BUT he took the cover off and said 'tracking inside - waters been dripping in - well I knew that there was a leaking gate valve by the pump, that weeped at high pressure, and I had suspected the pressure vessel, since pressure change hot tpocold was rather higher than i remembered... sure enough when he hit the schrader valve, out came water not air.. So new gate valve and pressure vessel in today and that's the next issue done with I hope.
So the failure mode was :
pressure vessel diaphragm=>over pressure=>blown gland in gate valve => water in electrics => RCD trip.