Okay, this is probably a terrible idea but just thinking aloud really.
We now have a home battery and an EV. The inverter system for the battery has a CT clamp that currently detects all consumption by the house and determines how much comes from the battery or grid etc.
As is common with these systems when you charge an EV at night say, one is apt to find one’s home battery has fully discharged trying to charge the EV which can be an issue if you were wanting to use your battery to power your house in the morning on cheap rate electricity stored overnight.
The “simple” solution that I read a lot about it to position the clamp so that it’s only monitoring in-house use, not power drawn by the EV charger. Easier said than done in my case.
My power lead from my meter goes into one Henley block where it splits into three. One wire for the domestic consumer unit, one wire for a mini consumer unit for the EV and the third to a consumer unit for the inverter & battery.
The clamp can only be fitted around one cable. It’s too small to squeeze two cables through.
So, if it isn’t shockingly bad practice, could one fit one Henley block to divide the power supply into two, one of the legs going to the EV charger and the second leg (with the CT clamp), going to a second Henley block supplying the domestic CU and the inverter/battery CU? Effectively the house and inverter/battery will now be getting power through two Henley blocks in series.
I’m sure that there are other solutions involving home automation and some software jiggery pokery but I like the idea of a solution that will simply “blind” the CT clamp to the demands of the EV charger.
Tim