My new water softener came with basically washing machine style hoses which will be useless for my high flow system.
Now, how would I connect fixed pipework to the fixings? The outlet/inlet is a plastic 3/4" male thread. Should I be using a 3/4" tap connector, 3/4" female iron and PTFE or something else?
A tap connector should be fine. The threads will be parallel, and will need a washer to seal - as opposed to sealing on tapered threads. You may need to dress the ends of the plastic fittings to ensure there are no burrs and/or use rubber washers rather than the usual fibre washers normally used with tap connectors.
If you need a degree of flexibility, you could use something like BES item:
13753 [Go to
formatting link
and then navigate to it - direct URLs don't seem possible on the BES site!] This is a braided hose with a 3/4" BSP tap connector one end, a 19mm bore, and a 22mm compression fitting at the other end. [I've got some of these on my bath taps - but make sure you order the washers separately - they don't come automatically!]
19mm isn't a bad bore, but I think I'll stick with the full 22mm. I want every last litre per minute out of it. Whilst my pressure is reasonable, it isn't brilliant, as I'm on top of a hill. The softener itself is going to lose me over 1 bar.
Another thought: Tap connectors usually have a shoulder or spigot on which the washer sits, and which is intended to go inside the tap tail. I have somethines found with plastic fittings - particularly on toilet cisterns - that the spigot *won't* go into the fitting, and needs to be filed back to less than the thickness of the washer in order to get a seal.
Yes. Presumably the plastic pipe is too thick. Shall I just go for a 3/4" iron and seal it? One of the main disadvantages of the tap connector is the much reduced bore through the middle, so a standard iron fitting should allow more flow.
Obviously with non-tapered threads, you just need to know when to stop, but it should seal fine against plastic with PTFE shouldn't it?
Nah. I'm running the entire house's water supply through it. Screwfix 52117 wouldn't have remotely enough flow rate through it. The 19mm bore one someone else suggested is actually quite tempting given that it is presumably inside diameter and so is really not far off that of 22mm copper. However, a smooth bored flowed bend 22mm copper setup seems more reliable to my mind.
tape isn't really any good on parallel threads - you need to seal on a
*face*. In this case, a rubber washer of suitable thickness would be best. It may need to be quite fat if the FI fitting has got a lot more thread than your plastic softener.