CopperWalker233

Two things to fix before you glue anything up. First, the sanitary tee on the vent is in backwards. You want the sweep of that fitting to follow the same direction the water flows in the drain, so flip it around. The way you've got it now, the sweep points back toward the…

Read the full reply

So a while back I asked on here about the drain for a laundry sink I extended and got a bunch of helpful feedback. Been a good learning expirience honestly, and I think I addressed most of it. Want to make sure I didn't miss anything before everything gets glued up for good. Here's what changed: I raised the AAV so it sits 6" above the rim of the sink, put a sanitary tee on the AAV, added pipe support, and added a backwater valve and a clean out. Also put a board along the bottom to mount everything to so it's not just floating. Flipped the ball valves around so they're right side up too, and swapped the 45 for a 90 where it ties into the drain. I know it'll never win any beauty contests but it's in the basement next to the washer, so I care more about it working right than looking pretty. Anything else I should fix or adjust before I commit with the glue? Being dry-fit is the one nice thing about PVC I guess.


Two things to fix before you glue anything up. First, the sanitary tee on the vent is in backwards. You want the sweep of that fitting to follow the same direction the water flows in the drain, so flip it around. The way you've got it now, the sweep points back toward the laundry sink instead of going with the flow. It's the same idea as a sanitary tee under a fixture, the curved side directs things downstream. And honestly, air doesn't really care which way a fitting sweeps, so it would probably work fine either way, but since you're dry-fitted there's no reason not to do it right. Second thing is the cleanout. Roll that wye up so the opening sits above the center line of the drain pipe. The reason is that if the line ever backs up, you want the cleanout access coming in from the top of the pipe, not the side or bottom. It makes snaking it way easier and keeps any mess from spilling out sideways when you open it.

Other than those two, from the way you put it, the setup sounds good. Raising the AAV above the rim like you did, the support, the backwater valve, mounting everything to a board, all of that is what people would have told you to do anyway. And yeah, being dry-fit right now is exactly why this is an easy fix. Pull the two fittings, reorient them, re-dry-fit, done. Maybe ten minutes of work. One habit from my own glue-ups: once you're happy with the fit, mark the fitting and pipe with a pencil line across each joint before gluing. That way everything goes back exactly where you checked it and you're not second-guessing alignment with primer on your hands.

glad you went with the board mount btw, that was the thing that actually made my own little basement project feel finished. having everything fixed in one spot instead of sagging wherever the pipe wanted to sit makes glue-up day way less stressful. also liking that you swapped that last fitting where it ties into the drain, gentler entry for the washer water. are you priming everything too or just cement? first time i did a pvc run i skipped primer and got lucky, wouldnt do it that way now.

I keep coming back to that line about air not caring which way a fitting sweeps. I'm not convinced. Air moving through a fitting with the sweep pointing the wrong way hits a sharp corner and has to redirect, same as water would, just less noticeably. On a vent it probly matters less because the flow is gentle, but 'probably works fine either way' feels like a wierd thing to say right after insisting it's backwards. If the direction truly made no difference, why flag it as a must-fix? Genuinely asking, not being a jerk. I'd flip it regardless, since you're dry-fit anyway, but I'd love to hear the actual reasoning spelled out.

Update: okay, the vent tee facing the wrong way makes sense now that it's been pointed out, easy enough to spin that around before glue-up. One thing I'm not clear on though. When you say roll the cleanout wye up so the opening sits above the centerline, do I rotate the whole fitting in place, or does that change how it ties into the run?