Well that's annoying/educational!

Following some part Q housing development here, I re-gained possession of a 60' x 15' steel frame lean-to. Having already erected it twice, once as originally intended and a second time after an exciting barn fire, (pics. available) I felt invested in a further use:-) I acquired a neighbouring yard in 1983 which had a range of buildings blown together from materials available to the demolition contractor owners at that time. One 55' x 16' blockwork wall barn build with an almost flat tarred felt roof seemed an ideal location as the existing roof was sagging badly and leaking. Some free steel I beam and 20' steel purlins salvaged from the housing job came my way and I was able to fabricate the extra 4 legs needed. Last week was part fit the roof week and today was the first opportunity to observe the impact of light rain.

Hmm. Not good:-( Agricultural roofing meeting BS5502 class 2 can slope at 12.5 degrees which mine does. The roof sheets are 18' long insulated steel sheet coated with a plastic finish. What appears to happen is that water droplets gather on the surface, eventually two neighbours mingle and start a run: gathering more droplets as they go and reaching the drip with sufficient energy to partly overshoot the 6"gutter!

Gutter position was always going to be an issue as the thickness of insulation and the 4" cut back drip are well across even a 6" gutter. The situation worsens as there is only one suitable place for the soak preventing a dual slope gutter and access is very restricted due to a lean-to glasshouse along most of the wall:-(

Current thinking is to see how it performs in different rain patterns with a fall back plan to fit a 90degree deflector to the roof edge. Need to avoid splash/mist gathering on the exposed insulation.

Reply to
Tim Lamb
Loading thread data ...

I added a simple [ section to mine with stitching screws. The lower legs of the channel section being bent a slightly more acute angle. I coated the inside with bitumastic paint and this became my end cap and gutter.

Reply to
AJH

snip

My first shallow pitch roof in AS35 insulated. The frame was built for big six and originally had an *eaves beam* gutter.

I have some left over Z section purlins and could halve those to stitch on.

It may be less of a problem with heavier rain..

Reply to
Tim Lamb