Venting through roof

Jul 03, 2019 Last reply: 7 years ago 5 Replies

They do a condensate trap fitting for duct....e.g. ...

formatting link
(First hit)

Spose depends on the angles whether it'll collect & theb where would you send it.... what about winter freeze ups? Etc.

I was bemoaning that I don't have a decent wall where I can exhaust a bathroom extractor. - Currently I have a in-line fan venting out just under the eaves. The roof is "pyramid shaped". I would like to change to a larger fan and someone suggested going out through the roof tiles.



Concerned about disturbing a watertight roof. Any experiences? Best outlets ?


The first thing that springs to mind is that you will need insulated ducting or risk condensation running back down the ducting.

And sit down before looking at the price of a vent tile.

"Jim K.." snipped-for-privacy@gmail.com wrote in news:Pa- snipped-for-privacy@brightview.co.uk:

Looks good

Do you really need a bigger outlet though? Brian

Can't say I've noticed but it's ceratinly a possibilty.

formatting link
£11.99 inc VAT but for a slate roof.

Bit of a PITA to fit as the slate positions didn't neatly fall between the rafters. And getting the sarking to be neat around the spigot was messy. Given our exposed location I bought a 12" square bit of soft rubber sheet, cut hole in middle just smaller than the spigot and tucked that below/above the sarking to provide a perfect wind (powder snow...) and waterproof seal.