New furnace just went in, does this look right to anyone?

Nov 25, 2026 Last reply: 18 hours ago 4 Replies
Saved reading

First reply

CobaltTony_1979

Honestly, from the way you describe it, that setup would fail inspection in my area without question. A long exhaust run going diagonally across open space instead of following the wall, loose wiring just dangling there, boxes screwed to studs with nothing finished off, none of…

Read the full reply

So we finally got the new furnace put in and the crew wrapped up today. It's sitting in an unfinished area, concrete foundation wall on one side, exposed studs on the other. They set a sheet metal plenum on top of it and hooked it into insulated flex ducts running along the ceiling. That part seems okay to my untrained eye. The thing that's bugging me is the exhaust vent. It's a long metal pipe running diagonally up across the whole room instead of hugging the wall or ceiling, and it just looks kind of awkward hanging out there. Is that a normal way to route it or should I be asking them to redo it?



Also the black gas pipe comes down the wall to the unit, which seems fine, but there's loose wiring still hanging around and electrical boxes just mounted on the studs to the right. Nothing looks connected or finished off yet. Did anyone else's install look this rough right at the end, or is this the kind of thing I should be calling the contractor back about before they consider it done?


Honestly, from the way you describe it, that setup would fail inspection in my area without question. A long exhaust run going diagonally across open space instead of following the wall, loose wiring just dangling there, boxes screwed to studs with nothing finished off, none of that flies with a city or county inspector. Which leads me to the bigger question: did anyone pull a permit for this? Because if a permit had been pulled, an inspector would have to sign off before the job is considered done, and this doesn't look like anything that would get a sign-off. My guess is no permit was ever filed, which is a whole separate problem on top of the workmanship itself. The exhaust routing is the part that jumps out at me. Venting has to be done to spec for the specific furnace, and a lazy diagonal run across a room is not how a competent crew leaves things. Same with the electrical. Even in an unfinished space, wiring and boxes get secured and roughed in properly. Loose conductors hanging around next to a gas appliance is not a 'we'll tidy that later' situation, or at least it shouldn't be if they were planning to call it done today.

As for the gas line coming down the wall, that alone doesn't tell you much either way, but combined with everything else you're describing, the whole install reads like a hack job to me. When mine went in, everything was either strapped, supported, or capped neatly by the time the crew left, and that's the baseline you should expect. If it were me, I'd be on the phone with the contractor first thing tomorrow asking straight up whether a permit was pulled and when their inspection is scheduled. But based on what you've laid out, I wouldn't fight to salvage this. I'd have them pull the whole system out and get a reputable company in to do it properly. You're about to live with this equipment for fifteen-plus years, and the difference between a clean install and a sloppy one shows up in every inspection, service call, and insurance question down the road.

The thing that stood out to me is that the crew wrapped up today and left wiring hanging loose like that. When my furnace went in, the lead guy walked me around the whole setup before they packed up and pointed at each piece, and anything unfinished was on a written punch list with a return date. So my question for you is, did they tell you they were coming back, or did they treat this as the finished job? Because that answer changes everything. If they considered it done with conductors dangling next to a gas appliance, that tells you what kind of crew you hired, and honestly I'd be done with them at that point.

That diagonal exhaust run would bug me too, and the thing is, that's not a finishing step they can come back and tidy up. It's a route they picked. Even if the wiring was always meant to wait for another visit, somebody chose to run that pipe straight across the room instead of hugging the concrete wall that's right there. I'd get a couple of photos of everything as it sits today, just so there's no arguing about condition later. Did they say anything when you asked about the venting, or did they just kind of shrug it off as normal?

I'll say the one thing from your list that still holds up is the gas pipe. A black pipe run down the wall to the unit is how it's been done forever, and it reads as the one piece they didn't rush. Same goes for the plenum sitting on top and feeding those insulated flex ducts, nothing wrong with that part as you tell it. The rest, well, back when I had mine done the crew wouldn't leave a room with wire hanging loose next to a gas appliance, finished space or not. Funny how some habits stick and some crews drop them. Did the crew say anything when they packed up, or just hand you a bill and go?