I had sat cables coming into the room and into the TV but having moved the TV they need extending and are exposed. There's new skirting going in so I could hide everything behind that but i'm not sure about the F-plugs, i've had them fail in the past and need trimming/refitting. Should they be OK buried or can anyone suggest a better solution?
Permanent alternative to F plug
May 31, 2022
Last reply: 4 years ago
17 Replies
I suppose you don't want to terminate them on wall boxes and then plug in extender cables from there?
I recently came across this:
formatting link
looks like a neat option for cables emerging from a wall. Intended for microbore pipework but no reason why it couldn't work for cables. Fits a standard backbox, although I suppose you could screw direct to a wall too.
Another option (depending on the aesthetic) is skirting trunking, which can be easily removed if access is needed.
Theo
Correctly fitted f plugs that are the correct size for the cable won't fail. Use two f plugs and an f line connector. Use the tug test. Wrap the whole thing tightly in self-amalgamating tape.
Bill
R D S submitted this idea :
Make a good solid f-plug pair of ends off, joint them with a f-plugback to back barrel connector, test them, then add a layer of self amalgamating tape over the top to keep moisture out.
williamwright formulated on Tuesday :
Snap!
+1
Fitted correctly they don't fail.
+1 Yup what they said :-)
Hmm, interesting. Why self-amalg tape and not heat shrink sleeve?
Heat shrink is not necessarily air tight (although adhesive lined would be ok). It's not massive mechanical protection you need so much as atmospheric.
on 31/05/2022, Cliff Topp supposed :
OK the sticky backed heat shrink sleaving, it is better able to seal and keep moisture out.
I have fitted BNC conectors to many GHz devices.
OK, They spent a time in a slightly damp corner* behind the TV, probably getting shunted about now and again, on a couple of occasions we'd no signal and I found myself trimming and reattaching. I'll do a better job of attaching them and seal.... Cheers.
*There's a rad there now, better back doors and skirtings.
If the cable end has been in a damp place the whole cable might need replacing.
Bill
Self-amalg takes a bit of practice to apply correctly, but I think it does a better job when used right.
Bill
F plugs are surprisingly good if they are fitted correctly and not being repeatedly undone etc.
The simple ‘twist on’ ones can be unreliable due to poor fitting. There is a type which needs a cheap tool, I think I paid a fiver. The tool forces a part of the connect under the braid and grips the insulation.
The ‘special’ plugs are a bit more expensive but still cheap.
formatting link
Wrap them in self amalgamating tape.
I had to undo one done like that recently - had been exposed to the elements for many years. Was in perfect condition.
I may be wrong, but I think that the black ones are more than good enough for the job, but the blue ones can be used, un-protected, outdoors.
Poor fitting means it's the wrong size. Beware of using one that's a bit too small because the internal thread can cut the folded-back braid.
It's a goldilocks thing.
Bill