Most of my attic has blown in insulation but above two of the rooms there's only yellow fiberglass batts sitting between the joists. No blow in over top of it at all. Those two rooms are noticeably colder than the rest of the house, and my sister lives in one of them and says it's basically freezing in there during winter. So I'm trying to figure out where the heat is escaping and this seems like the obvious weak spot. My question is what to do about it. Should I rent a blower and cover the yellow stuff with blown in? Or would it be better to pull the batts out entirely and lay new rolled insulation down? I've also seen people just put unfaced rolled insulation right over top of what's already there, which would be the easiest option if it actually works. Anyone dealt with a setup like this? Wondering which route makes the most sense before I start dragging stuff up into the attic.
Yellow batts above two rooms, blown in everywhere else - what's the best fix?
Nov 22, 2026
Last reply: 10 hours ago
2 Replies
Follow replies to this discussion?
First reply
You can rent a blower and go right over the top of those batts, that works fine. No need to rip anything out first. But before you blow anything, spend a day air sealing that section, and honestly that's prolly where a big chunk of your cold rooms problem is coming from anyway.…
Read the full replyInformation here may be outdated?
You can rent a blower and go right over the top of those batts, that works fine. No need to rip anything out first. But before you blow anything, spend a day air sealing that section, and honestly that's prolly where a big chunk of your cold rooms problem is coming from anyway. Grab a few cans of expanding foam and seal every crack you can find. Top plates where the walls meet the attic, every hole where wire or pipe pokes through, around light fixtures. The nice thing about having batts down there is you can peel them back, foam the gaps, then lay them back down and blow over the whole thing. It's cheap and honestly kind of fun, spraying foam around up there.
Here's why this matters with batts specifically. Where wires run through a batt, the insulation gets shoved aside and compressed, and you end up with open channels running right down to the sheetrock. Those are serious heat loss spots. It looks mostly fine from above but the cavities aren't acutally full. Blown-in does a much better job of filling around all that stuff and sealing the gaps, which is exactly why the rooms under your blown-in sections behave better. So my route would be: air seal first, then blow loose fill over the batts and bring those sections up to match the depth you've got everywhere else in the attic. Don't stress about hitting some specific number, just get it thick and even with the rest.
Two things to watch while you're doing it. Keep the new insulation clear of any recessed lights and flues, that's a fire issue. And staple baffles at the eaves before you blow, so the loose fill doesn't slide down and block the soffit vents. I'd skip the option of laying rolled batts over top. It's the easiest to drag up there but it won't fill in around the wires and gaps the way loose fill will, and that's the exact problem you're trying to fix.
Reading this made me realize how little I know, I didn't even know you could rent the machine and spray the fluffy stuff yourself. I always figured that yellow rolled stuff and the loose fluffy kind needed to go on separately, not layered.
One thing I'm curious about since my own half-baked attic plans are creeping up on me: when you put the loose stuff on top, does it matter which way up the yellow stuff underneath is? Like if the paper backing is facing the wrong way, is that a problem, or does it not matter once it's covered?
Join the Discussion
Have something to add? Share your thoughts — no account required.
Didn't find your answer?