central heating problem

Hi Why does a central heating radiator heat up when the heating is switched off at the boiler but the hot water taps are run? Any suggestions please? TIA Phil

Reply to
PP
Loading thread data ...

My bathroom rad does the same. It's the nearest in line to the boiler & the heat radiates to it when the boiler kicks in to provide hot water.

Don.

Reply to
Don Spumey

What sort of system are you talking about?

Combi, gravity, pumped??

Reply to
EricP

Combi. It's an old boiler (Myson Midas), and two radiators have stopped working. I think they may be blocked.

Reply to
PP

A common problem caused by thermo syphon currents which is eliminated by the installation of a flap valve in the central heating pipework feed. The flap stays shut preventing thermo syphon currents but when the pump is started it has enough power to move it to the open position

Reply to