Pilot light blows out - high winds

First winter in house CH boiler is a (dont laugh) Wickes 40 the pilot light keeps being blown out or at least, there appears to be a correleation between high winds and no heating in the house Any ideas to cure the problem Boiler to be replaced next year when funds allow thanks

Reply to
Vass
Loading thread data ...

| First winter in house | CH boiler is a (dont laugh) Wickes 40 | the pilot light keeps being blown out | or at least, there appears to be a correleation between high winds | and no heating in the house | Any ideas to cure the problem | Boiler to be replaced next year when funds allow | thanks

In the case of pilot light problems, first replace the thermocouple. These are cheap readily available and easy to replace. Everything else costs more and is more difficult.

--=20 Dave Fawthrop Sick of Premium SMS scams, SMS marketing, Direct marketing phone calls, Silent phone calls?=20 Register with

formatting link
they work :-)

Reply to
Dave Fawthrop

In article , Dave Fawthrop writes

Agreed, and clean the crap from around the pilot jet.

What is the flue type? Conventional, room sealed (balanced). Flue location, exposed, between 2 buildings?

Reply to
fred

the boiler is in the airing cupboard at the top of the stairs (1st floor) the flue goes horizontally straight out the wall behind the boiler on the gable end of the house, no other buildings within 60 feet

Reply to
Vass

Could be it's rather weedier than it should be through crud in the jet.

Reply to
Dave Plowman (News)

If it is wind, the problem should only occur with certain wind = directions. Turbulence means that the wind direction at the flue may be massively different from general wind direction, so the *local* wind may blow directly into the flue when the general wind is from the other side of = the house :-(

--=20 Dave Fawthrop Sick of Premium SMS scams, SMS marketing, Direct marketing phone calls, Silent phone calls?=20 Register with

formatting link
they work :-)

Reply to
Dave Fawthrop

In article , Vass writes

Ok, balanced flue so this shouldn't happen (wind pressure on the exhaust should be balanced by wind pressure on the inlet), pilot must be pretty shitty for it to be susceptible, give it a a clean & make sure the thermocouple is positioned correctly at the tip of the flame.

Reply to
fred

Thanks Fred, will do this first Have found a supplier of the Thermocouple in Newcastle in case i need one Thanks to all on this one.

Reply to
Vass