Low cold water pressure

Oct 22, 2010 21 Replies

I think the problem is that they use a wedge shaped metal shutter (a bit like a sluice gate) thats forced into a shaped metal groove to shut the water off. It only needs the tiniest bit of scale in the groove or any other crud to stop the shutter closing all the way.

A proper stopcock uses a rubber/metal interface and doesn't suffer from this problem.

Tim

If used part open (or even fully open in soft corrosive water areas) the gate can erode either due top cavitation or corrosion, sometimes resulting in full flow, otherwise a failure to cut off completely.

I've given up using gate valves.