Why is my Midea U-shaped AC still covered in mold after the recall fix?

Oct 03, 2026 Last reply: 6 hours ago 3 Replies
Saved reading

First reply

cal.harper

The reality is those drilled drain holes only fix outdoor base pan pooling, not the moisture sitting inside the indoor blower assembly. becasue inverter units cycle down to low speeds rather than cycling completley off, the evaporator coil stays cool and damp for hours on end.…

Read the full reply

Got my 10k BTU Midea U-shaped window unit serviced last year under that recall notice, and the tech basially just drilled a couple of drain holes in the base pan. I figured that would solve the standing water issue, but I peeked past the front louvers today and the entire cylindrical blower wheel is coated in this thick, dark fuzzy buildup. It looks like straight-up mold on every single little fin. It has that damp basement smell every time the compressor kicks on. It's frustrating because everyone swears these U-shaped inverters are the best units on the market, and it relly is quiet, but is there just no way around moisture staying trapped in the fan housing? I don't know if I shold spend a weekend taking the casing apart to scrub the fan wheel or just replace the whole thing. If I do replace it, are the newer models any better about draining, or will any inverter unit end up doing this?


The reality is those drilled drain holes only fix outdoor base pan pooling, not the moisture sitting inside the indoor blower assembly. becasue inverter units cycle down to low speeds rather than cycling completley off, the evaporator coil stays cool and damp for hours on end. Add in the fact that the basic mesh screen lets plenty of fine household dust slip right past, and you get wet dust adhering to the blower wheel fins. Mold is pretty much inevitable once that mix sits in the dark. You don't necessarily have to toss the machine, but cleaning it properly means taking off the front plastic shroud and the Styrofoam housing around the squirrel cage fan. I pull mine outside at the start of every season, spray the wheel down with foaming coil cleaner, and work between every fin with an old bottle brush before rinsing it out. It's tedious work, but it completely clears that musty smell. A good habit once it's clean is running the AC in **fan-only mode** for twenty or thirty minutes before you shut it off for the day so the housing dries out completely.

If you'd rather not deal with a major teardown every year, you might want to look away from the deep U-shape designs. Traditional window units or the **LG Dual Inverter** models tend to have better internal airflow thru the chassis. They don't trap damp air in quite the same way, so while all window units eventually collect dust, they don't turn into sealed terrariums anywhere near as fast.

100% on having to pull the shroud off, but just be super careful with that little temprature sensor clipped to the styrofoam housing. It has almost no slack in the wire, and if you yank the foam forward without popping the clip, you'll rip the wire right out and throw an E1 error on the screen. Also throw a plastic grocery bag taped over the control board on the right side before you rinse that blower wheel. Water loves to sneak into that compartment if you aren't careful.

What worked for me without doing a full teardown was using a cheap 1-gallon pump sprayer loaded with warm water and Dawn, followed by a mist of Concrobium mold control so the spores don't bounce right back. Also check your pitch. When I mounted mine, I leveled it by the book, but water was still sitting in that front trough under the blower wheel. I stuck an extra 1/4" shim under the indoor sill bracket to force a harder backward tilt toward the outside. That extra slope dumps the standing water immediately and stopped the swamp smell for good.