Woodburner Installation

Hi,

I'm about to install a woodburning stove. It will need an external twin wall stainless steel flue on an outside wall. I have a few questions and would be grateful if any experts can answer them.

My stove has an 8" outlet. Can I use 12" flue outside rather than 8" ? ( I can get some 12" cheap !)

Will this increase or effect the 'draw' in any way ?

I plan on slightly less than 1 metre of stove pipe above the stove going into the 12" Flue pipe. Does this sound reasonable ?

Thanks

Stu

Reply to
Stu
Loading thread data ...

No expert but I've been researching coz I'm planning to fit a second (woodburning) boiler working in tandem with my gas-fired one.

From what I've read 9ins is considered the limit for domestic flues. The reason is that above 9ins the wider part of the flue won't get warm enough to "draw" the smoke effectively, probably resulting in some smokiness within the room.

riccip

Reply to
riccip

Eight inch flue does sound rather large to start with. =

I have a Bont Esse solid fuel (Anthracite) room heater that also does nine radiators.= It is rated at 12kWatts. I also burn wood on this during the spring/autumn months. =

The flue size is five inch diameter. This comes out of the back of the stove and then goe= s 90=C2=B0 and up into a very old clay liner that is eliptical in shape and about 11" on t= he major axis. This change in cross sectional area does slow the flow rate down consid= erably and I do get some smoke blow back occasionally. I've been told that I could run a= new 5" liner all the way up to increase the draw.

So basically 8" does sound a bit large but if that is what is fitted then I wouldn't go an= y larger.

x-- 100 Proof News -

formatting link
30+ Days Binary Retention with High Completion x-- Access to over 1.9 Terabytes per Day - $8.95/Month x-- UNLIMITED DOWNLOAD

Reply to
Chris McBrien

I'll second Adrian's comment on the 'Coolie Hat' to cover the chimney pot. =

My solid fuel stove has been out for a couple of days, due to warm weather (in Scotland?= ). Just a few showers was enough to dislodge some soot and block the 90=C2=B0 bend at th= e back of the boiler. It takes ten minutes with the vacuum cleaner and a long piece of pi= pe to suck it out.

x-- 100 Proof News -

formatting link
30+ Days Binary Retention with High Completion x-- Access to over 1.9 Terabytes per Day - $8.95/Month x-- UNLIMITED DOWNLOAD

Reply to
Chris McBrien

That's about twice the area - not a hope. You'll get sod-all draught and the tarry soot will chill out in no time.

Even 8" sounds on the large size for a domestic woodburner.

Reply to
Andy Dingley