Combi boiler conversion & driping bath taps

I had my boiler changed form a old gravity fed system to a new mains pressure combi. Everything is great. The central heating warms up the house a lot quicker. However, my bath taps (and only the baths taps) tend to drip. It takes a great effort to turn them off. i have taken to using a pipe rench to turn them off. Is there some adjustment I can make ? or do i need to get the converted to a different design? thanks

Reply to
John
Loading thread data ...

I expect that your taps are a bit worn. When the water came from a tank in the loft (via the cylinder for the hot) the pressure was pretty low so the worn taps were enough to stop the flow. Now you have a combi your taps are trying to hold back the full pressure of the mains.

Fear not! It is likely that a few minutes with a tap reseating tool (such as this

formatting link
and a couple of new washers and everything will be back to normal.

It's not a difficult job - if you know how to change a tap washer it's just an extra minute or so twisting the tool inside the tap before fitting the new washer.

However - if you keep graunching the taps closed with a pipe wrench they aren't going to last much longer!!

I am a little disappointed (but not surprised!) that the plumber who changed the boiler didn't check all of your taps afterwards because this must happen almost every other time he fits a combi!!