Latest threads in Home Repairshow only best voted threads

Subject Author Posted Replies
 
Instead of a right angle drive, how about a light duty T-drive?
Desperately seeking sources for a T-drive. What I mean by that is something like these. Milwaukee 48-06-2871 (right angle drive) or 49-22-8510 (right angle drill attachment) General Tools 924 Metabo...
9
9
 
smoke detector recommendations?
I have two smoke detectors in my house which are over 8 years old, plus one CO detector. Since the smoke detectors are near end of life, I'd like to improve the coverage. I also need new detectors in...
10
10
 
Ice Dams
We presently have substantial ice dams on a roof that was done about a year and a half ago (complete rip-off of old shingles down to plywood, installed 30-year GAF architectural shingles). Our...
18
18
 
F-connector installation tool for RG-6 quad shield?
Hi all bought a roll of quad shield a while ago and still have a good bit left. Still find myself occasionally needing to make up a cable. Connectors are damn near impossible to install on this stuff;...
17
17
 
Use house heating or halogen far-infrared heater for one person?
Let's say I stay upstairs alone in a 2600 sq ft 2-story house. I can turn on the gas heater of the house for upstairs only, set the thermostat to (say) 70 F. Or I can use a personal haolgen...
13
13
 
tracing a sewage line
I'd like to root out my waste line running to the sewer. It appears to me that this runs through a neighbors property, a long way to go, before it dumps in the sewer. I'd like to find exactly where my...
36
36
 
Converting L.P. appliances to Natural Gas Question(s)
I am in the process of switching over from LP to natural gas ... the line is roughed in, and I need to get conversion kits for my appliances before making the connection. I have a TAPPAN 30-4980-3204...
20
20
 
quality of "durable" goods?
I bought a galvanized water tank about 5 years ago. It had multiple pin- holes after 3 years. I bought a replacement bathtub for a house at about the same time. It has spalling and severe corrosion in...
9
9
 
Cable Company Vans and Orange Cones
a.h.r. relate: The house across the street from me had a 2nd floor toilet let go soon after a young couple bought the house. They hadn't moved in yet and the water ran for close to 24 hours before...
24
24
 
Rheem Classic HVAC Condenser - Run Capacitor Replacement
I recently cleaned out the coils on our Rheem Classic condenser and also took the time to take some pictures of the run capacitor replacement procedure. I have experience replacing a capacitor on our...
4
4
 
OT SUV must have hard top??
U-haul says for ttrailer rental: Must be equipped with a hard top if it is an SUV or Jeep. U-Haul does not allow any type of sport-utility vehicle not equipped with a hard top to tow U-Haul equipment....
14
14
 
One problem with snowblowers
Reverse is too damn slow!
16
16
 
Odd electrical problem
So the ice storm the othe day took down many trees in our area. My BIL called me because a branch fell and knocked his neutral wire loose from the weatherhead. Some things worked others didn't,...
36
36
 
How much of a toilet's power....
....comes from the water stored in the tank, vs the incoming water pressure? I'm referring to an old style toilet, not some dubious low flush annoy-o-lator.
57
57
 
Generator Problem
I have a 5,500 watt gasoline engine generator that powers the furnace, refrigerator and water pump during power outages. It's run well for the last 6 or 7 years but has gotten tempermental lately....
13
13