Just ask the leccy board to fit an isolator (free in our area - ex- manweb) and maybe a cutout change / fuse upgrade (if it`s an old iron clad with porcelain fuses).
--
Please add "[newsgroup]" in the subject of any personal replies via email
* old email address "btiruseless" abandoned due to worm-generated spam *
  Click to see the full signature.
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload

Ask for an upgrade. 40A is well low. Then have the 25mm tails ready for them to connect up. Ensure your earthing and consumer unit is up to scratch. (i.e. says 100A maximum).
Christian.