A simple question, is the 150mm gap between the cold water feed and the heating vent pipe a maximum or a minimum?
Second question, Why?
Richard
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
Tricky Dicky wrote:

Max
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload

so as to minimize the difference in pressure between the two points, to reduce the risk of pumping over or sucking air into the system.
I'm sure this is all in the FAQ (or if it's not it should be).
cheers
-- John Stumbles -+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ -+ Question Authority