Best Way To heat a warehouse

Howya Folks I'm trying to figure out the best way to heat a medium sized factory , 30m by 40m with 12m ceiling , its basically a small warehouse converted to suit our expanded production,cuurently we have gas fired forced air heaters but we are looking for a system with less manual interaction and preferably elevated , can anybody recommend a cost effective system thast easy to install and cheap to run Cheers Kieran
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
wrote:

Use big big blocks of Ice. Everyone will then wear big Parka's and you wont need to use heat. Bubba
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
kfinnan wrote:

Electric Infrared.
Jake
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
Jake wrote:

sheesh only a sparky would think that....
he said he had gas, so the correct answer is gas infrared.
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload

OK.. OK... I missed the 'gas' part.
If you've got gas in the building, gas infrared is a much better choice... with lots of zoning for any infrared.
Jake
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
Hey Jake i was looking at infrared , we have a low air flow in the factory , what exactly do you mean by zoning , and why is gas better , we were possibly looking at moving away from gas cheers Kieran
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
wrote:

hehehe. "Yeah Jake, c'mon. Why?" :-) Bubba
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
kfinnan wrote:

Whats cheaper over there 80% effiecient gas or electricity.
Gas fired infrared be a failry economical installation, cheaper than multiple unit heaters I would suppose.
http://www.rezspec.com/cms_download.php?mod_files [fileid]0000000896
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload

Small thermo-nuclear weapon.
That'll heat things up nice and quick.
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
Archie Leach wrote:

I thought carry grant was dead
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
gaspacks with duct socks work well.

Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
kfinnan wrote:

Thats almost a 40 ft ceiling, if the place was a little bigger area wise I would almost think of air turn over units