Close coupled suite


Should the cistern be fixed to the wall in all cases ?? A local plumber fitted the suite abt 18 months ago and now I find a leak has developed between the pan and cistern due to the movement of the pan/cistern when used..I have tightened the screws that bolt the pan/cistern together but after a while they leak again..I did notice that the fixing holes in the back of the cistern had not been used...
--


Thanks Ted

Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload

Yes the cistern should be fastened to the wall.
Adam
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload
ARWadsworth wrote:

Thanks...Called the firm who installed it and spoke to the gaffer chap told him it was not fixed correctly and he is coming out tomorrow to see and fix it....
--
Regards
Ted Wager G3TPI
  Click to see the full signature.
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload

It will probably need a new doughnut washer between the pan and cistern once it's started leaking. They aren't reusable as they deform to the shape of the parts.
--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
  Click to see the full signature.
Add pictures here
<% if( /^image/.test(type) ){ %>
<% } %>
<%-name%>
Add image file
Upload